The Smarten Superb 3075 Is A Solar Inverter Of The MPPT Type, Capable Of Handling Loads Of Up To 2 KW. This Inverter Has A Voc Range Of 100V Vdc, Allowing You To Use 36/60/72 Cell Solar Panels. It Comes With A 50A Current Rating Solar Charge Controller.
You Can Install Solar Panels Of Up To 2 KW On This Inverter, Making It Suitable For Loads Of Around 2 KW. By Using 2 KW Panels, You Can Create A Robust Solar System Of 2 KW With This Inverter.
This Inverter Operates On 24V, So You Will Need To Connect 2 Batteries To It. Those Who Require Less Battery Backup Can Use 100 Ah Batteries For A Cost-Effective Option. For Longer Backup, 150 Ah Or 200 Ah Batteries Can Be Used.
The Output Of This Inverter Is Pure Sine Wave, Ensuring That All Your Devices Function Smoothly. It Comes With A 2-Year Warranty. You Can Initially Use This Inverter As A Regular Inverter And Later Add Solar Panels To Turn It Into A Solar Inverter.
Smarten Superb 3075 24V 50A MPPT Solar Inverter Price is ₹18,999
1kw Solar System With Batteries Price In India
Smarten Superb 3075 Specifications
The Smarten Superb 3075 is a 2.25kW hybrid solar power conditioning unit (PCU) for off-grid applications. It is designed for commercial spaces and can run a 1-ton inverter technology air-conditioner.It can run a 1HP water motor pump (tested brands: Lubi, Havells, Kirloskar, Usha etc).
MAINS INPUT MODE | |
Mains AC low cut UPS mode | 175VAC ± 10VAC |
Mains AC low cut recovery UPS mode | 185VAC ± 10VAC |
Mains AC high cut UPS mode | 265VAC ± 10VAC |
Mains AC high cut recovery UPS mode | 255VAC ± 10VAC |
Mains AC low cut WUPS mode | 90VAC ± 10VAC |
Mains AC low cut recovery W.UPS mode | 110VAC ± 10VAC |
Mains AC high cut WUPS mode | 295VAC ± 10VAC |
Mains AC high cut recovery W.UPS mode | 285VAC ± 10VAC |
Input Frequency Range | 40Hz to 60Hz |
Voltage Output in Mains Mode | Same as input |
Mains Charging Enable/Disable | Yes Provided,you can set by front switch |
Frequency Output in Mains Mode | Same as input |
BATTERY
It has a selectable 4 levels for battery’s depth of discharge. It can charge from mains up to 90 Volts.
Battery Type | LA / Tubular / SMF |
DC input voltage | 24V |
Battery Quantity 12V 100Ah to 220Ah | 2 |
Float charging voltage | 27.4V±0.2V |
Boost charging voltage for LA Battery | 28V±0.3V |
Boost charging voltage for Tubular and SMF Battery | 28.8V±0.3V |
Bulk Absorption Battery Voltage | 29.6±0.2V |
Battery deep Discharge Recovery | Yes (Independent Charger to Recover Deep Discharge Battery) |
Mains Charging Current Enable/Disable | Yes Provide by Keypad |
Charging Current By Grid | 15A±3A |
BACKUP MODE
It has an advanced DSP controller for efficient working and protection against overload, short circuit, over temperature, etc.
Output voltage | 220VAC±10% |
Output frequency | 50Hz ± 0.2 Hz |
Output waveform | Pure Sine Wave ≤ 5% THD |
No Load current | <1.5A |
Capacity | 3075VA |
Discharging current @ full load | 90A ± 2A |
Low Battery Warning | 21.6V±0.2V |
Low Battery Cut | 20.8V±0.2V |
Change over time UPS mode | < 10msec |
Change over time WUPS mode | < 25msec |
Switching Element | MOSFET |
Cooling | Temp. Controlled Fan |
PROTECTIONS
It has an advanced DSP controller for efficient working and protection against overload, short circuit, over temperature, etc.
Overload in backup mode | Yes provided, system will indicate on display at 101% load |
Short Circuit in Backup Mode | System will shutdown aGer 3 – retries in case of output short circuit |
Short Circuit in Mains Mode | Mains MCB will trip |
Back feed | System will shutdown in case of back feed and there is no retry |
Over temperature | Yes provided, if heat sink temperature goes above 100°C System will shut down |
Reverse Battery | DC fuse will blown |
Phase to Phase protection in mains mode | Yes provided by electronic |
Solar Charge Controller
It has an in-built 50-ampere advanced maximum power point tracking (MPPT) technology-based charge controller.
Solar Charge Controller type | MPPT |
Max Panel wattage can be connected | 1800WATT |
PV Voltage Range | 35V – 100±2V |
Maximum Battery current | 50Amp. |
Efficiency | > 93% |
Reverse PV protection | Yes provided, it will also display on LCD panel |
Switches | Menu (Select),UP,Down,Esc. |
Reverse current flow to PV | Yes provided |
Sharing of current when PV and Grid Both are available | If PV power is not sufficient enough to charge the battery, system will start sharing battery charging from PV and grid. |
DOD definition (Depth of Discharge) | Mains will be connect when battery voltage reach at defined value of the battery voltage. |
DOD (Depth of Discharge) |
20%- if battery voltage is 25.0v±0.2V |
30%- if battery voltage is 24.0v±0.2V | |
40%- if battery voltage is 23.0v±0.2V | |
50%- if battery voltage is 22.0v±0.2V | |
MODE SELECTION | SOLAR>>BATTERY>>GRID
SOLAR>>GRID>>BATTERY |
Display and Alarms
It has a LCD display that shows various parameters such as battery voltage, solar voltage, load current, etc.
LCD_Initial_Display | Welcome, SMARTEN Website Address, System Capacity, Charging Till 90VAC and Deep Discharge Battery,
System Setting, UPS / WUPS mode, I/P range 90-295VAC / 170-265VAC, Battery Type Selected LA / SMF / Tubular, DOD. |
LCD Status Display |
Mains ON, Input Voltage, Input Frequency, Battery Voltage, Battery Charging, Battery Charged, Charging Current, Backup Mode, UPS ON, UPS OFF, Battery Voltage, Load %, Output Voltage, Output Frequency, Battery Current, PV Current,PV Voltage.
Mains Low Cut, Mains High Cut, Mains Not Available, Mains Frequency Cut |
LCD Fault / Protection Status Display | Mains Fuse Blown / MCB Trip, Short Circuit, Overload, Battery Low, High Temperature, Back feed |
Buzzer | Mains Fuse Blown / MCB Trip, Short Circuit, Overload, Battery Low, High Temperature, Back feed |
Safety
HV Test Input to Earth | Leakage current <5mA when 1.5kV applied for 1 min |
HV Test Output to Earth | Leakage current <5mA when 1.5kV applied for 1 min |
IR Test Input to Earth | >5MΏ between @ 500VDC |
IR Test Output to Earth | >5MΏ between @ 500VDC |
Earth Leakage current in Mains mode | < 2.5mA |
Earth Leakage current in Backup mode | < 2.5mA |
Environment
Operating Temperature | 0°C to 50°C |
Storage Temperature | 0°C to 50°C |
Operating Relative Humidity | 90% Non-Condensing |
DIMENSIONS | |
Dimensions in mm | 415x320x415 |
Luminous Best Solar Inverter Price In India
Features
Specifications and features of the Smarten Superb 3075 24Volt 50AMP MPPT Solar PCU Inverter. Here are some of the main points. Smarten Superb 3075 24V 50A MPPT Solar Inverter Price
- Supports double battery.
- Advanced DSP control technology.
- 30 % more efficient MPPT Solar Charge Controller.
- Operating Input AC Voltage 90-290V.
- Smart charging even during low voltage 90V.
- DOD, can set four battery discharge levels. (20%, 30%, 40%, 50%)
- Grid charging enable/disable option for reduced electricity bill.
- Preference to Solar Power over Grid Power.
- Supports a wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF)
- Recover deep discharge battery even Zero volt zero gravity.
- SUPERB PCU can run heavy loads like 1HP Submersible, Photocopiers, Refrigerator, washing machine etc., depending on their capacity (please check the inverter capacity and your power requirement)
- Sine wave output for safety of your sensitive appliances and noiseless operations.
- Complete protection from back feed and phase to phase supply.
- MCB for protection from Input mains.
- Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep- discharge etc
- LCD Display to easily understand status of mains availability, battery status, solar status etc.
Disclaimer: The Price & Specs Shown May Be Different From Actual. Please Confirm Before Purchasing.